Contact us
|
Home
|
Login
| Users Online: 361
Feedback
Subscribe
Advertise
Search
Advanced Search
Month wise articles
Figures next to the month indicate the number of articles in that month
2022
January
[
3
]
2021
November
[
2
]
September
[
3
]
August
[
1
]
June
[
2
]
January
[
1
]
2020
November
[
3
]
August
[
1
]
July
[
1
]
May
[
1
]
February
[
1
]
2019
December
[
2
]
September
[
1
]
August
[
2
]
July
[
2
]
June
[
1
]
May
[
1
]
April
[
1
]
March
[
1
]
February
[
2
]
2018
December
[
4
]
November
[
1
]
August
[
1
]
July
[
1
]
May
[
1
]
2017
October
[
1
]
September
[
3
]
June
[
1
]
May
[
1
]
March
[
1
]
February
[
1
]
2016
April
[
1
]
March
[
1
]
January
[
2
]
2015
October
[
3
]
September
[
3
]
June
[
4
]
March
[
2
]
January
[
1
]
2014
October
[
2
]
September
[
2
]
August
[
2
]
July
[
1
]
June
[
1
]
May
[
1
]
March
[
1
]
January
[
2
]
2013
December
[
2
]
November
[
1
]
July
[
1
]
June
[
1
]
March
[
2
]
2012
December
[
1
]
September
[
3
]
August
[
1
]
July
[
1
]
April
[
3
]
March
[
1
]
February
[
1
]
2011
August
[
2
]
July
[
2
]
June
[
1
]
May
[
1
]
March
[
2
]
January
[
1
]
2010
October
[
3
]
» Articles published in the past year
To view other articles click corresponding year from the navigation links on the left side.
All
|
Abstracts
|
Book Review
|
Commentary
|
Editorial
|
Letters to Editor
|
Original Article
|
Original Articles
|
PV16 Abstracts
|
Research Article
|
Review Articles
|
Symposium
|
Technical Note
Export selected to
Endnote
Reference Manager
Procite
Medlars Format
RefWorks Format
BibTex Format
Show all abstracts
Show selected abstracts
Export selected to
Add to my list
Research Article:
Robotic telecytology for remote cytologic evaluation without an on-site cytotechnologist or cytopathologist: an active quality assessment and experience of over 400 cases
Sahussapont Joseph Sirintrapun, Dorota Rudomina, Allix Mazzella, Rusmir Feratovic, William Alago, Robert Siegelbaum, Oscar Lin
J Pathol Inform
2017, 8:35 (7 September 2017)
DOI
:10.4103/jpi.jpi_25_17
PMID
:28966835
Background:
The first satellite center to offer interventional radiology procedures at Memorial Sloan Kettering Cancer Center opened in October 2014. Two of the procedures offered, fine needle aspirations and core biopsies, required a rapid on-site cytologic evaluation of smears and biopsy touch imprints for cellular content and adequacy. The volume and frequency of such evaluations did not justify hiring on-site cytotechnologists, and therefore, a dynamic robotic telecytology (TC) solution was created. In this article, we provide data on our experience with this active implementation. Sakura VisionTek was selected as our robotic TC solution.
Methods:
A retrospective analysis of all TC evaluations from this satellite site was performed. Information was collected on demographics, lesion location, imaging modality; a comparison of TC-assisted adequacy with final adequacy was also conducted.
Results:
An analysis of 439 cases was performed over a period of 23 months with perfect correlation in 92.7% (407/439) of the cases. An adequacy upgrade (inadequate specimen becomes adequate) in 6.6% (29/439) of the cases. An adequacy downgrade (adequate specimen becomes inadequate), is near zero at 0.7% (3/439) of the cases.
Conclusions:
Dynamic robotic TC is effective for immediate evaluations performed without on-site cytotechnology staff. The overall intent of this article is to present data and concordance rates as outcome metrics. Thus far, such outcome metrics have exceeded our expectations. Our TC implementation shows high, perfect concordance. Adequacy upgrades are minor but more relevant and impressive is a near zero adequacy downgrade. Our full implementation has been so successful that plans are in place for configurations at future satellite sites.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (5) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
Successful secure high-definition streaming telecytology for remote cytologic evaluation
Sahussapont Joseph Sirintrapun, Dorota Rudomina, Allix Mazzella, Rusmir Feratovic, Oscar Lin
J Pathol Inform
2017, 8:33 (7 September 2017)
DOI
:10.4103/jpi.jpi_18_17
PMID
:28966833
Background:
The use of minimally invasive procedures to obtain material for diagnostic purposes has become more prevalent in recent years. As such, there is increased demand for immediate cytologic adequacy assessment of minimally invasive procedures. The array of different locations in which rapid on-site evaluation (ROSE) is expected requires an ever-increasing number of cytology personnel to provide support for adequacy assessment. In our study, we describe the implementation process of a telecytology (TC) system in a high case volume setting and evaluate the performance of this activity.
Methods:
We performed retrospectively an analysis of all consecutive remote TC ROSE evaluations obtained for 15 months. The specimens were evaluated using a TC system. The ROSE adequacy assessment obtained at the time of the procedure was compared to the final cytopathologist-rendered adequacy assessment when all the material was available for review, including the alcohol-fixed preparations.
Results:
A total of 8106 distinct cases were analyzed. TC-assisted preliminary adequacy assessment was highly concordant with the final cytopathologist-rendered adequacy assessment. Perfect concordance or accuracy was at 93.1% (7547/8106). The adequacy upgrade rate (inadequate specimen became adequate) was 6.8% (551/8106), and the initial adequacy downgrade (adequate specimen became inadequate) was <0.1% (8/8106).
Conclusions:
The TC outcome demonstrates high concordance between the initial adequacy assessment and final cytopathologist-rendered adequacy assessment. Adequacy upgrades were minor but, more importantly, our results demonstrate a minimal adequacy downgrade. The process implemented effectively eliminated the need for an attending pathologist to be physically present onsite during a biopsy procedure.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (6) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
A design study investigating augmented reality and photograph annotation in a digitalized grossing workstation
Joyce A Chow, Martin E Törnros, Marie Waltersson, Helen Richard, Madeleine Kusoffsky, Claes F Lundström, Arianit Kurti
J Pathol Inform
2017, 8:31 (7 September 2017)
DOI
:10.4103/jpi.jpi_13_17
PMID
:28966831
Context:
Within digital pathology, digitalization of the grossing procedure has been relatively underexplored in comparison to digitalization of pathology slides.
Aims:
Our investigation focuses on the interaction design of an augmented reality gross pathology workstation and refining the interface so that information and visualizations are easily recorded and displayed in a thoughtful view.
Settings and Design:
The work in this project occurred in two phases: the first phase focused on implementation of an augmented reality grossing workstation prototype while the second phase focused on the implementation of an incremental prototype in parallel with a deeper design study.
Subjects and Methods:
Our research institute focused on an experimental and “designerly” approach to create a digital gross pathology prototype as opposed to focusing on developing a system for immediate clinical deployment.
Statistical Analysis Used:
Evaluation has not been limited to user tests and interviews, but rather key insights were uncovered through design methods such as “
rapid ethnography
” and “
conversation with materials
”.
Results:
We developed an augmented reality enhanced digital grossing station prototype to assist pathology technicians in capturing data during examination. The prototype uses a magnetically tracked scalpel to annotate planned cuts and dimensions onto photographs taken of the work surface. This article focuses on the use of qualitative design methods to evaluate and refine the prototype. Our aims were to build on the strengths of the prototype's technology, improve the ergonomics of the digital/physical workstation by considering numerous alternative design directions, and to consider the effects of digitalization on personnel and the pathology diagnostics information flow from a wider perspective. A proposed interface design allows the pathology technician to place images in relation to its orientation, annotate directly on the image, and create linked information.
Conclusions:
The augmented reality magnetically tracked scalpel reduces tool switching though limitations in today's augmented reality technology fall short of creating an ideal immersive workflow by requiring the use of a monitor. While this technology catches up, we recommend focusing efforts on enabling the easy creation of layered, complex reports, linking, and viewing information across systems. Reflecting upon our results, we argue for digitalization to focus not only on how to record increasing amounts of data but also how these data can be accessed in a more thoughtful way that draws upon the expertise and creativity of pathology professionals using the systems.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (1) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Sitemap
|
What's New
Feedback
|
Copyright and Disclaimer
|
Privacy Notice
© Journal of Pathology Informatics | Published by Wolters Kluwer -
Medknow
Online since 10
th
March, 2010