Contact us
|
Home
|
Login
| Users Online: 353
Feedback
Subscribe
Advertise
Search
Advanced Search
Month wise articles
Figures next to the month indicate the number of articles in that month
2022
January
[
3
]
2021
November
[
2
]
September
[
3
]
August
[
1
]
June
[
2
]
January
[
1
]
2020
November
[
3
]
August
[
1
]
July
[
1
]
May
[
1
]
February
[
1
]
2019
December
[
2
]
September
[
1
]
August
[
2
]
July
[
2
]
June
[
1
]
May
[
1
]
April
[
1
]
March
[
1
]
February
[
2
]
2018
December
[
4
]
November
[
1
]
August
[
1
]
July
[
1
]
May
[
1
]
2017
October
[
1
]
September
[
3
]
June
[
1
]
May
[
1
]
March
[
1
]
February
[
1
]
2016
April
[
1
]
March
[
1
]
January
[
2
]
2015
October
[
3
]
September
[
3
]
June
[
4
]
March
[
2
]
January
[
1
]
2014
October
[
2
]
September
[
2
]
August
[
2
]
July
[
1
]
June
[
1
]
May
[
1
]
March
[
1
]
January
[
2
]
2013
December
[
2
]
November
[
1
]
July
[
1
]
June
[
1
]
March
[
2
]
2012
December
[
1
]
September
[
3
]
August
[
1
]
July
[
1
]
April
[
3
]
March
[
1
]
February
[
1
]
2011
August
[
2
]
July
[
2
]
June
[
1
]
May
[
1
]
March
[
2
]
January
[
1
]
2010
October
[
3
]
» Articles published in the past year
To view other articles click corresponding year from the navigation links on the left side.
All
|
Abstract
|
Book Review
|
Commentary
|
Editorial
|
Letters
|
Original Articles
|
Research Article
|
Review Articles
|
Technical Note
Export selected to
Endnote
Reference Manager
Procite
Medlars Format
RefWorks Format
BibTex Format
Show all abstracts
Show selected abstracts
Export selected to
Add to my list
Research Article:
Using XML to encode TMA DES metadata
Oliver Lyttleton, Alexander Wright, Darren Treanor, Paul Lewis
J Pathol Inform
2011, 2:40 (24 August 2011)
DOI
:10.4103/2153-3539.84233
PMID
:21969921
Background:
The Tissue Microarray Data Exchange Specification (TMA DES) is an XML specification for encoding TMA experiment data. While TMA DES data is encoded in XML, the files that describe its syntax, structure, and semantics are not. The DTD format is used to describe the syntax and structure of TMA DES, and the ISO 11179 format is used to define the semantics of TMA DES. However, XML Schema can be used in place of DTDs, and another XML encoded format, RDF, can be used in place of ISO 11179. Encoding all TMA DES data and metadata in XML would simplify the development and usage of programs which validate and parse TMA DES data. XML Schema has advantages over DTDs such as support for data types, and a more powerful means of specifying constraints on data values. An advantage of RDF encoded in XML over ISO 11179 is that XML defines rules for encoding data, whereas ISO 11179 does not.
Materials and Methods:
We created an XML Schema version of the TMA DES DTD. We wrote a program that converted ISO 11179 definitions to RDF encoded in XML, and used it to convert the TMA DES ISO 11179 definitions to RDF.
Results:
We validated a sample TMA DES XML file that was supplied with the publication that originally specified TMA DES using our XML Schema. We successfully validated the RDF produced by our ISO 11179 converter with the W3C RDF validation service.
Conclusions:
All TMA DES data could be encoded using XML, which simplifies its processing. XML Schema allows datatypes and valid value ranges to be specified for CDEs, which enables a wider range of error checking to be performed using XML Schemas than could be performed using DTDs.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (1) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
The accuracy of dynamic predictive autofocusing for whole slide imaging
Richard R McKay, Vipul A Baxi, Michael C Montalto
J Pathol Inform
2011, 2:38 (24 August 2011)
DOI
:10.4103/2153-3539.84231
PMID
:21969919
Context:
Whole slide imaging (WSI) for digital pathology involves the rapid automated acquisition of multiple high-power fields from a microscope slide containing a tissue specimen. Capturing each field in the correct focal plane is essential to create high-quality digital images. Others have described a novel focusing method which reduces the number of focal planes required to generate accurate focus. However, this method was not applied dynamically in an automated WSI system under continuous motion.
Aims:
This report measures the accuracy of this method when applied in a rapid continuous scan mode using a dual sensor WSI system with interleaved acquisition of images.
Methods:
We acquired over 400 tiles in a "stop and go" scan mode, surveying the entire z depth in each tile and used this as ground truth. We compared this ground truth focal height to the focal height determined using a rapid 3-point focus algorithm applied dynamically in a continuous scanning mode.
Results:
Our data showed the average focal height error of 0.30 (±0.27) μm compared to ground truth, which is well within the system's depth of field. On a tile by tile assessment, approximately 95% of the tiles were within the system's depth of field. Further, this method was six times faster than acquiring tiles compared to the same method in a non-continuous scan mode.
Conclusions:
The data indicates that the method employed can yield a significant improvement in scan speed while maintaining highly accurate autofocusing.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (7) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
Computer-aided identification of prostatic adenocarcinoma: Segmentation of glandular structures
Yahui Peng, Yulei Jiang, Laurie Eisengart, Mark A Healy, Francis H Straus, Ximing J Yang
J Pathol Inform
2011, 2:33 (26 July 2011)
DOI
:10.4103/2153-3539.83193
PMID
:21845231
Background:
Identification of individual prostatic glandular structures is an important prerequisite to quantitative histological analysis of prostate cancer with the aid of a computer. We have developed a computer method to segment individual glandular units and to extract quantitative image features, for computer identification of prostatic adenocarcinoma.
Methods:
Two sets of digital histology images were used: database I (n = 57) for developing and testing the computer technique, and database II (n = 116) for independent validation. The segmentation technique was based on a k-means clustering and a region-growing method. Computer segmentation results were evaluated subjectively and also compared quantitatively against manual gland outlines, using the Jaccard similarity measure. Quantitative features that were extracted from the computer segmentation results include average gland size, spatial gland density, and average gland circularity. Linear discriminant analysis (LDA) was used to combine quantitative image features. Classification performance was evaluated with receiver operating characteristic (ROC) analysis and the area under the ROC curve (AUC).
Results:
Jaccard similarity coefficients between computer segmentation and manual outlines of individual glands were between 0.63 and 0.72 for non-cancer and between 0.48 and 0.54 for malignant glands, respectively, similar to an interobserver agreement of 0.79 for non-cancer and 0.75 for malignant glands, respectively. The AUC value for the features of average gland size and gland density combined via LDA was 0.91 for database I and 0.96 for database II.
Conclusions:
Using a computer, we are able to delineate individual prostatic glands automatically and identify prostatic adenocarcinoma accurately, based on the quantitative image features extracted from computer-segmented glandular structures.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (10) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
A data model and database for high-resolution pathology analytical image informatics
Fusheng Wang, Jun Kong, Lee Cooper, Tony Pan, Tahsin Kurc, Wenjin Chen, Ashish Sharma, Cristobal Niedermayr, Tae W Oh, Daniel Brat, Alton B Farris, David J Foran, Joel Saltz
J Pathol Inform
2011, 2:32 (26 July 2011)
DOI
:10.4103/2153-3539.83192
PMID
:21845230
Background:
The systematic analysis of imaged pathology specimens often results in a vast amount of morphological information at both the cellular and sub-cellular scales. While microscopy scanners and computerized analysis are capable of capturing and analyzing data rapidly, microscopy image data remain underutilized in research and clinical settings. One major obstacle which tends to reduce wider adoption of these new technologies throughout the clinical and scientific communities is the challenge of managing, querying, and integrating the vast amounts of data resulting from the analysis of large digital pathology datasets. This paper presents a data model, which addresses these challenges, and demonstrates its implementation in a relational database system.
Context:
This paper describes a data model, referred to as Pathology Analytic Imaging Standards (PAIS), and a database implementation, which are designed to support the data management and query requirements of detailed characterization of micro-anatomic morphology through many interrelated analysis pipelines on whole-slide images and tissue microarrays (TMAs).
Aims:
(1) Development of a data model capable of efficiently representing and storing virtual slide related image, annotation, markup, and feature information. (2) Development of a database, based on the data model, capable of supporting queries for data retrieval based on analysis and image metadata, queries for comparison of results from different analyses, and spatial queries on segmented regions, features, and classified objects.
Settings and Design:
The work described in this paper is motivated by the challenges associated with characterization of micro-scale features for comparative and correlative analyses involving whole-slides tissue images and TMAs. Technologies for digitizing tissues have advanced significantly in the past decade. Slide scanners are capable of producing high-magnification, high-resolution images from whole slides and TMAs within several minutes. Hence, it is becoming increasingly feasible for basic, clinical, and translational research studies to produce thousands of whole-slide images. Systematic analysis of these large datasets requires efficient data management support for representing and indexing results from hundreds of interrelated analyses generating very large volumes of quantifications such as shape and texture and of classifications of the quantified features.
Materials and Methods:
We have designed a data model and a database to address the data management requirements of detailed characterization of micro-anatomic morphology through many interrelated analysis pipelines. The data model represents virtual slide related image, annotation, markup and feature information. The database supports a wide range of metadata and spatial queries on images, annotations, markups, and features.
Results:
We currently have three databases running on a Dell PowerEdge T410 server with CentOS 5.5 Linux operating system. The database server is IBM DB2 Enterprise Edition 9.7.2. The set of databases consists of 1) a TMA database containing image analysis results from 4740 cases of breast cancer, with 641 MB storage size; 2) an algorithm validation database, which stores markups and annotations from two segmentation algorithms and two parameter sets on 18 selected slides, with 66 GB storage size; and 3) an in silico brain tumor study database comprising results from 307 TCGA slides, with 365 GB storage size. The latter two databases also contain human-generated annotations and markups for regions and nuclei.
Conclusions:
Modeling and managing pathology image analysis results in a database provide immediate benefits on the value and usability of data in a research study. The database provides powerful query capabilities, which are otherwise difficult or cumbersome to support by other approaches such as programming languages. Standardized, semantic annotated data representation and interfaces also make it possible to more efficiently share image data and analysis results.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (16) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
Modified full-field optical coherence tomography: A novel tool for rapid histology of tissues
Manu Jain, Nidhi Shukla, Maryem Manzoor, Sylvie Nadolny, Sushmita Mukherjee
J Pathol Inform
2011, 2:28 (14 June 2011)
DOI
:10.4103/2153-3539.82053
PMID
:21773059
Background:
Here, we report the first use of a commercial prototype of full-field optical coherence tomography called Light-CT
TM
. Based on the principle of white light interferometry, Light-CT
TM
generates quick high-resolution three-dimensional tomographic images from unprocessed tissues. Its advantage over the current intra-surgical diagnostic standard,
i.e.
frozen section analysis, lies in the absence of freezing artifacts, which allows real-time diagnostic impressions, and/or for the tissues to be triaged for subsequent conventional histopathology.
Materials and Methods:
In this study, we recapitulate known normal histology in nine formalin fixed
ex vivo
rat organs (skin, heart, lung, liver, stomach, kidney, prostate, urinary bladder, and testis). Large surface and virtually sectioned stacks of images at varying depths were acquired by a pair of 10x/0.3 numerical aperture water immersion objectives, processed and visualized in real time.
Results:
Normal histology of the following organs was recapitulated by identifying various tissue microstructures. Skin: epidermis, dermal-epidermal junction and hair follicles with surrounding sebaceous glands in the dermis. Stomach: mucosa with surface pits, submucosa,
muscularis propria
and serosa. Liver: hepatocytes separated by sinusoidal spaces, central veins and portal triad. Kidney: convoluted tubules, medullary rays (straight tubules) and collecting ducts. Prostate: acini and fibro-muscular stroma. Lung: bronchi, bronchioles, alveolar ducts, alveoli and pleura. Urinary bladder: urothelium,
lamina propria
,
muscularis propria
, and
serosa
. Testis: seminiferous tubules with intra-tubular sperms.
Conclusion:
Light-CT
TM
is a powerful imaging tool to perform fast histology on fresh and fixed tissues, without introducing artifacts. Its compact size, ease of handling, fast image acquisition and safe incident light levels makes it well-suited for various intra-operative and intra-procedural triaging and decision making applications.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (19) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
Interinstitutional and interstate teleneuropathology
Clayton A Wiley, Geoff Murdoch, Anil Parwani, Terry Cudahy, David Wilson, Troy Payner, Kim Springer, Terrence Lewis
J Pathol Inform
2011, 2:21 (11 May 2011)
DOI
:10.4103/2153-3539.80717
PMID
:21633488
Background:
Telemedicine has emerged as an efficient means of distributing professional medical expertise over a broad geographic area with few limitations to the various services that can be provided around the globe. Telepathology is particularly well suited to distributing subspecialty expertise in certain environments in an economical fashion, while preserving centers of excellence.
Materials and Methods:
After a decade of intrainstitutional teleneuropathology for intraoperative consultation, we expanded our practice to cross state lines and communicate between geographically and financially separate medical centers.
Results:
The result was an effective means of distributing neuropathological expertise while at the same time preserving a professional center of excellence. While technical and legal (i.e., physician licensing) barriers were surmounted, expected and unexpected issues related to communication required commitment on the part of multiple individuals with diverse expertise and responsibilities.
Conclusion:
Lessons learned from this successful venture can be used to facilitate future efforts in this ever-growing practical vehicle for distributing pathology subspecialty expertise.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (13) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
Extending the tissue microarray data exchange specification for inclusion of data analysis results
Oliver Lyttleton, Alexander Wright, Darren Treanor, Philip Quirke, Paul Lewis
J Pathol Inform
2011, 2:17 (31 March 2011)
DOI
:10.4103/2153-3539.78263
PMID
:21572505
Background:
The Tissue Microarray Data Exchange Specification (TMA DES) is an eXtensible Markup Language (XML) specification for encoding TMA experiment data in a machine-readable format that is also human readable. TMA DES defines Common Data Elements (CDEs) that form a basic vocabulary for describing TMA data. TMA data are routinely subjected to univariate and multivariate statistical analysis to determine differences or similarities between pathologically distinct groups of tumors for one or more markers or between markers for different groups. Such statistical analysis tests include the
t
-test, ANOVA, Chi-square, Mann-Whitney
U
, and Kruskal-Wallis tests. All these generate output that needs to be recorded and stored with TMA data.
Materials and Methods:
We propose extending the TMA DES to include syntactic and semantic definitions of CDEs for describing the results of statistical analyses performed upon TMA DES data. These CDEs are described in this paper and it is illustrated how they can be added to the TMA DES. We created a Document Type Definition (DTD) file defining the syntax for these CDEs, and a set of ISO 11179 entries providing semantic definitions for them. We describe how we wrote a program in R that read TMA DES data from an XML file, performed statistical analyses on that data, and created a new XML file containing both the original XML data and CDEs representing the results of our analyses. This XML file was submitted to XML parsers in order to confirm that they conformed to the syntax defined in our extended DTD file. TMA DES XML files with deliberately introduced errors were also parsed in order to verify that our new DTD file could perform error checking. Finally, we also validated an existing TMA DES XML file against our DTD file in order to demonstrate the backward compatibility of our DTD.
Results:
Our experiments demonstrated the encoding of analysis results using our proposed CDEs. We used XML parsers to confirm that these XML data were syntactically correct and conformed to the rules specified in our extended TMA DES DTD. We also demonstrated that this extended DTD was capable of being used to successfully perform error checking, and was backward compatible with pre-existing TMA DES data which did not use our new CDEs.
Conclusions:
The TMA DES allows Tissue Microarray data to be shared. A variety of statistical tests are used to analyze such data. We have proposed a set of CDEs as an extension to the TMA DES which can be used to annotate TMA DES data with the results of statistical analyses performed on that data. We performed experiments which demonstrated the usage of TMA DES data containing our proposed CDEs.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (2) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
The tissue microarray data exchange specification: Extending TMA DES to provide flexible scoring and incorporate virtual slides
Alexander Wright, Oliver Lyttleton, Paul Lewis, Philip Quirke, Darren Treanor
J Pathol Inform
2011, 2:15 (15 March 2011)
DOI
:10.4103/2153-3539.78038
PMID
:21572508
Background:
Tissue MicroArrays (TMAs) are a high throughput technology for rapid analysis of protein expression across hundreds of patient samples. Often, data relating to TMAs is specific to the clinical trial or experiment it is being used for, and not interoperable. The Tissue Microarray Data Exchange Specification (TMA DES) is a set of eXtensible Markup Language (XML)-based protocols for storing and sharing digitized Tissue Microarray data. XML data are enclosed by named tags which serve as identifiers. These tag names can be Common Data Elements (CDEs), which have a predefined meaning or semantics. By using this specification in a laboratory setting with increasing demands for digital pathology integration, we found that the data structure lacked the ability to cope with digital slide imaging in respect to web-enabled digital pathology systems and advanced scoring techniques.
Materials and Methods:
By employing user centric design, and observing behavior in relation to TMA scoring and associated data, the TMA DES format was extended to accommodate the current limitations. This was done with specific focus on developing a generic tool for handling any given scoring system, and utilizing data for multiple observations and observers.
Results:
DTDs were created to validate the extensions of the TMA DES protocol, and a test set of data containing scores for 6,708 TMA core images was generated. The XML was then read into an image processing algorithm to utilize the digital pathology data extensions, and scoring results were easily stored alongside the existing multiple pathologist scores.
Conclusions:
By extending the TMA DES format to include digital pathology data and customizable scoring systems for TMAs, the new system facilitates the collaboration between pathologists and organizations, and can be used in automatic or manual data analysis. This allows complying systems to effectively communicate complex and varied scoring data.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
[Sword Plugin for Repository]
Beta
Research Article:
Barriers and facilitators to adoption of soft copy interpretation from the user perspective: Lessons learned from filmless radiology for slideless pathology
Emily S Patterson, Mike Rayo, Carolina Gill, Metin N Gurcan
J Pathol Inform
2011, 2:1 (7 January 2011)
DOI
:10.4103/2153-3539.74940
PMID
:21383925
Background:
Adoption of digital images for pathological specimens has been slower than adoption of digital images in radiology, despite a number of anticipated advantages for digital images in pathology. In this paper, we explore the factors that might explain this slower rate of adoption.
Materials and Method:
Semi-structured interviews on barriers and facilitators to the adoption of digital images were conducted with two radiologists, three pathologists, and one pathologist's assistant.
Results:
Barriers and facilitators to adoption of digital images were reported in the areas of performance, workflow-efficiency, infrastructure, integration with other software, and exposure to digital images. The primary difference between the settings was that performance with the use of digital images as compared to the traditional method was perceived to be higher in radiology and lower in pathology. Additionally, exposure to digital images was higher in radiology than pathology, with some radiologists exclusively having been trained and/or practicing with digital images. The integration of digital images both improved and reduced efficiency in routine and non-routine workflow patterns in both settings, and was variable across the different organizations. A comparison of these findings with prior research on adoption of other health information technologies suggests that the barriers to adoption of digital images in pathology are relatively tractable.
Conclusions:
Improving performance using digital images in pathology would likely accelerate adoption of innovative technologies that are facilitated by the use of digital images, such as electronic imaging databases, electronic health records, double reading for challenging cases, and computer-aided diagnostic systems.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (9) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Sitemap
|
What's New
Feedback
|
Copyright and Disclaimer
|
Privacy Notice
© Journal of Pathology Informatics | Published by Wolters Kluwer -
Medknow
Online since 10
th
March, 2010